THREE-WAY REGULATION VALVE WITH PNEUMATIC DRIVE FOR NON AGGRESSIVE FLUIDS AND STEAM FLOW THROUGH REGULATION
|
|
|
connecting voltage: |
220V 50 Hz
24V 50 Hz |
| power supply pressure: |
1.5 - 6 bar |
| pneumatic drive size:
|
300 cm2
600 cm2
1200 cm2 |
| environment working temperature:
|
-20 to +60 °C |
| regulation media temperature: |
2 to 220 °C |
| valve position donor: |
Potentiometer 100 W,
1000 W
Current signal 4 to 20 mA two-wire |
| controlling drive: |
Input signal
4 to 20 mA
0.2 -1 bar |
| Nominal pressure |
PN 16 |
| Nominal aperture DN |
|
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
| Valve length L |
|
130 |
150 |
160 |
180 |
200 |
230 |
290 |
310 |
350 |
| Flange diameter D |
|
95 |
105 |
115 |
140 |
150 |
165 |
185 |
200 |
220 |
| Diameter DK |
|
65 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
180 |
| Height H1 (standard) |
|
65 |
75 |
80 |
90 |
100 |
115 |
145 |
155 |
175 |
| Height H1 (on demand) |
|
|
|
|
|
|
|
|
|
|
Pneumatic closing drive
1.5 - 6 bara
|
300 cm2 |
|
|
|
|
|
|
|
|
|
| 600 cm2 |
|
|
|
|
|
|
|
|
|
ORDER DATA |
Nominal valve's aperture |
| Nominal pressure |
| Maximum expected difference of pressure between input and output valves, or
wanted closing force |
| Pneumatic drive size |
| Controlling signal |
| Type of valve position donor |
| Regulation media |
| Flow through |
| THREE-WAY REGULATION VALVE'S CATALOGUE NUMBERS |
| Mark RV3E |
2000 |
X |
X |
X |
X |
X |
X |
|
| Nominal aperture DN/ flow through kvs |
1 |
|
|
|
|
|
15 mm / 4 kvs |
|
2
|
|
|
|
|
|
20 mm / 6.3 kvs |
|
3
|
|
|
|
|
|
25 mm / 10 kvs |
|
4
|
|
|
|
|
|
32 mm / 16 kvs |
|
5
|
|
|
|
|
|
40 mm / 25 kvs |
|
6
|
|
|
|
|
|
50 mm / 40 kvs |
|
7
|
|
|
|
|
|
65 mm / 63 kvs |
|
8
|
|
|
|
|
|
80 mm / 100 kvs |
|
9
|
|
|
|
|
|
100 mm / 145 kvs |
|
Z
|
|
|
|
|
|
on demand |
| Closing force for electro-moric drives |
1
|
|
|
|
|
0.5 kN |
|
2
|
|
|
|
|
2 kN |
|
3
|
|
|
|
|
4 kN |
|
4
|
|
|
|
|
12 kN |
|
5
|
|
|
|
|
on demand
|
| Pneumatic drive size |
A
|
|
|
|
|
300 cm2 |
|
B
|
|
|
|
|
600 cm2 |
|
C
|
|
|
|
|
1200 cm2 |
|
D
|
|
|
|
|
on demand
|
| Nominal pressure |
1
|
|
|
|
16 bar |
|
2
|
|
|
|
|
|
3
|
|
|
|
|
| Controlling signal |
0
|
|
|
|
|
1
|
|
|
voltage 220 V AC
|
|
2
|
|
|
voltage 24 V AC
|
|
3
|
|
|
voltage 0 - 10 V
DC |
|
4
|
|
|
current 4 - 20 mA |
|
5
|
|
|
0.2
- 1 bar |
|
6
|
|
|
on demand |
|
7
|
|
|
|
| Donor |
0
|
|
without donor |
|
1
|
|
potentiometer 100 W
|
|
2
|
|
current signal 4 - 20 mA |
|
3
|
|
voltage signal 0 - 10
V |
|
4
|
|
on demand |
|
5
|
|
|
| Step restriction and signalling |
0
|
|
|
1
|
moment switch |
|
2
|
border contact |
|
3
|
combination 1+2 |
|
4
|
electro-motoric
|