Home pageTemperature sensors

THERMOMETER FOR SMOKE CANALS





Connecting head: type B
Measuring element:
1 x Pt 100
1 x Pt 1000
1 x Fe-CuNi
1 x Ni-CrNi
2 x Pt 100
2 x Pt 1000
2 x Fe-CuNi
2 x Ni-CrNi
Protection pipe: prochrome
W.nr. 1.4301
f 15
Measuring area: for Pt100 and Pt 1000
0 - 400 °C
0 - 650 °C

for FeCuNi and NiCrNi
0 - 800 °C
Standard lengths: l = 500 mm
l = 710 mm
l = 1000 mm
Mounting: Flange (delivered on special demand)

max. temperature

measuring element

protection pipe

length

single

double


400 °C


Pt 100

W.Nr.1.4301

Æ 15 mm

500

TD211111

TD211112

710

TD211121

TD211122

1000

TD211131

TD211132


650 °C


Pt 100

W.Nr.1.4301

Æ 15 mm

500

TD212111

TD212112

710

TD212121

TD212122

1000

TD212131

TD212132


400 °C


Pt 1000

W.Nr.1.4301

Æ 15 mm

500

TD221111

TD221112

710

TD221121

TD221122

1000

TD221131

TD221132


650 °C


Pt 1000

W.Nr.1.4301

Æ 15 mm

500

TD222111

TD222112

710

TD222121

TD222122

1000

TD222131

TD222132


800 °C


Fe-CuNi

W.Nr.1.4301

Æ 15 mm

500

TD233111

TD233111

710

TD233121

TD233121

1000

TD233131

TD233131


800 °C


Ni-CrNi

W.Nr.1.4301

Æ 15 mm

500

TD243111

TD243111

710

TD243121

TD243121

1000

TD243131

TD243131


Note: Other dimension available on special demand



THERMOMETER FOR SMOKE CANALS

                 

Mark

TD

X

X

X

X

X

X

X

 
Type of connected head

2

           

connecting head type B

Sensor type

1

         

Pt100

2

         

Pt1000

3

         

Fe-CuNi

4

         

Ni-CrNi

Temperature area

1

       

to 400 °C

2

       

to 650 °C

3

       

to 800 °C

Protection pipe

1

     

W.Nr.1.4301 Æ 15

Meas. part length (L)

1

 

500 mm

2

 

710 mm

3

 

1000 mm

Number of thermoelements

1

single

2

double



Measuring inserted piece's and protection pipe's dimension for thermometers with head B